          MNS低壓抽屜柜可以靠墻安裝嗎?

          發布時間:2021-06-30 來源:http://www.qfpsy.com/ 瀏覽量:

          關于低壓抽屜柜的安裝規范還有以下規定:
          There are also the following provisions on the installation specification of low-voltage drawer cabinet:
          1、配電室的位置應靠近用電負荷中心,設置在塵埃少、腐蝕介質少、干燥和震動輕微的地方,并宜適當留有發展余地。
          1. The distribution room should be located close to the power load center, where there is less dust, less corrosive medium, dry and slight vibration, and there should be room for development.
          2、配電設備的布置必須遵循、可靠、適用和經濟等原則,并應便于安裝、操作、搬運、檢修、試驗和監測。
          2. The layout of distribution equipment must follow the principles of safety, reliability, applicability and economy, and should be convenient for installation, operation, handling, maintenance, test and monitoring.
          3、配電室內除本室需用的管道外,不應有其它的管道通過。室內管道上不應設置閥門和中間接頭;水汽管道與散熱器的連接應采用焊接。配電屏的上方不應敷設管道。
          3. In the power distribution room, there should be no other pipes except the pipes needed in the room. Valves and intermediate joints shall not be set on indoor pipelines; The connection between water vapor pipeline and radiator shall be welded. No pipe shall be laid above the distribution panel.
                                   MNS低壓抽屜柜
          4、落地式配電箱的底部宜抬高,室內宜高出地面 50mm 以上,室外應高出地面200mm 以上。底座周圍應采取封閉措施,并應能防止鼠、蛇類等小動物進入箱內。
          4. The bottom of the floor type distribution box should be raised, the indoor should be higher than the ground by more than 50 mm, and the outdoor should be higher than the ground by more than 200 mm. Sealing measures shall be taken around the base to prevent mice, snakes and other small animals from entering the box.
          5、同一配電室內并列的兩段母線,當任一段母線有一級負荷時,母線分段處應設防火隔斷措施。
          5. For two sections of bus in parallel in the same distribution room, when any section of bus has first-class load, fire isolation measures shall be set at the section of bus.
          6、當高壓及低壓配電設備設在同一室內時,且二者有一側柜頂有裸露的母線,二者之間的凈距不應小于 2m。
          6. When the high-voltage and low-voltage distribution equipment are located in the same room, and there is an exposed bus on one side of the cabinet top, the clear distance between the two should not be less than 2m.
          7、成排布置的配電屏,其長度超過 6m 時,屏后的通道應設兩個出口,并宜布置在通道的兩端,當兩出口之間的距離超過15m 時,其間尚應增加出口。
          7. When the length of the distribution panel arranged in rows exceeds 6m, the channel behind the panel should be set with two outlets, which should be arranged at both ends of the channel. When the distance between the two outlets exceeds 15m, the outlet should be added between them.
          8、成排布置的配電屏。
          8. Distribution boards arranged in rows.
          以上是"低壓抽屜柜能靠墻安裝嗎?"的介紹,相信大家都有所了解了,如想了解更多精彩資訊請點擊我們的網站:MNS低壓抽屜柜http://www.qfpsy.com
          Can low voltage drawer cabinet be installed against the wall If you want to know more wonderful information, please click our website: MNS low voltage drawer cabinet http://www.qfpsy.com .
          首頁首頁 產品產品 電話電話 置頂置頂
          国产精品亚洲二区在线观看_国语自产拍在线视频中文_亚洲国产精品国语在线_亚洲欧美色αv在线影视

          1. <sub id="9rq65"><pre id="9rq65"><delect id="9rq65"></delect></pre></sub>
            <u id="9rq65"></u> <i id="9rq65"><bdo id="9rq65"><delect id="9rq65"></delect></bdo></i>
          2. <u id="9rq65"></u>
            1. <rp id="9rq65"><ins id="9rq65"><i id="9rq65"></i></ins></rp>

                <i id="9rq65"></i>
                色欧美久久久久久久免费看 | 婷婷色免费看片 | 午夜亚洲精品无遮挡 | 亚洲国产一区二区97 | 亚洲色婷婷5月 | 亚洲精品欧美日韩在线 |